C02706 | min. s-ramp time, C02707 | permissible direction of rot, C02708 | limited speed – Lenze 9400 User Manual
Page 885: C02709 | limited speed [rpm, C02708/1, C02708/2, C02708/3, C02708/4, C02706, C02707

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
885
14
Parameter reference
14.2
Parameter list | C02706
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02706
C02707
C02708
C02709
Parameter | Name:
C02706 | Min. S-ramp time
Data type: UNSIGNED_32
Index: 21869
d
= 556D
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
10000 100 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02707 | Permissible direction of rot.
Data type: UNSIGNED_32
Index: 21868
d
= 556C
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Positive and negative
1 Positive only
2 Negative only
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02708 | Limited speed
Data type: INTEGER_32
Index: 21867
d
= 556B
h
Basic function "
Setting range
(min. value | unit | max. value)
0.0000
Unit/s
214748.3647
Subcodes
Lenze setting
Info
C02708/1
3600.0000 Unit/s
Limited speed 1 ... 4
C02708/2
7200.0000 Unit/s
C02708/3
14400.0000 Unit/s
C02708/4
28800.0000 Unit/s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02709 | Limited speed [rpm]
Data type: INTEGER_32
Index: 21866
d
= 556A
h
Basic function "
Display range
(min. value | unit | max. value)
0.0
rpm
214748364.7
Subcodes
Info
C02709/1
Limited speed 1 ... 4
C02709/2
C02709/3
C02709/4
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10