Parameter list | C00058
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00058
C00059
C00060
C00061
C00062
C00063
Parameter | Name:
C00058 | Pole position
Data type: INTEGER_32
Index: 24517
d
= 5FC5
h
Setting range
(min. value | unit | max. value)
-179.9
°
179.9
Subcodes
Lenze setting
Info
C00058/1
-90.0 °
Resolver pole position
C00058/2
0.0 °
Encoder pole position
C00058/3
0.0 °
Module pole position
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00059 | Motor - number of pole pairs
Data type: UNSIGNED_32
Index: 24516
d
= 5FC4
h
Display range
(min. value | unit | max. value)
0
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00060 | Rotor position
Data type: INTEGER_32
Index: 24515
d
= 5FC3
h
Display range
(min. value | unit | max. value)
0
2047
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00061 | Heatsink temperature
Data type: INTEGER_32
Index: 24514
d
= 5FC2
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00062 | Temperature inside the controller
Data type: INTEGER_32
Index: 24513
d
= 5FC1
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00063 | Motor temperature
Data type: INTEGER_32
Index: 24512
d
= 5FC0
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer