C00214 | required safety module, C00218 | application: id number, C00214 – Lenze 9400 User Manual
Page 760: 14 parameter reference

14
Parameter reference
14.2
Parameter list | C00214
760
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00214
C00217
C00218
C00219
C00225
Parameter | Name:
C00214 | Required safety module
Data type: UNSIGNED_8
Index: 24361
d
= 5F29
h
Setting of the expected safety module
• If a different safety module is detected, a fault (trouble) will be activated. The fault can only be reset by mains
switching.
Selection list
(Lenze setting printed in bold)
1 SM0
2 SM100
4 SM300
5 SM301
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00217 | Parameter error information
Data type: UNSIGNED_32
Index: 24358
d
= 5F26
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00218 | Application: ID number
Data type: UNSIGNED_32
Index: 24357
d
= 5F25
h
Display range
(min. value | unit | max. value)
0
0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00219 | CAN/EPL device type
Data type: UNSIGNED_32
Index: 24356
d
= 5F24
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00225 | Check configuration
Data type: UNSIGNED_32
Index: 24350
d
= 5F1E
h
This code is for device-internal use only and must not be written to by the user!