Page 206: Synchronous machines, Field weakening for synchronous machines ( 206), V2.0, 5motor interface

5
Motor interface
5.8
Parameterisable additional functions
206
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.8.2
Field weakening for synchronous machines
This function is available from software version V2.0!
If required, the field weakening mode can be switched on in
for synchronous machines.
[5-28] Voltage/speed characteristic with switched-on field weakening
[5-29] Calculation of the maximally reachable speed with switched-on field weakening
[5-30] Speed/torque characteristics of a synchronous servo motor with field weakening
Note!
Function only possible for servo control!
Armature control range
Field weakening range
• When field weakening is switched on, the motor
magnetising current is increased from 0 A to the maximally
effective magnetising current via an internal control loop
when the voltage limit is reached.
• As a result, a higher speed can be reached at the same
motor voltage or DC-bus voltage.
n
U
motor
n
max
n
rated_mot
800V
2 U
rated_mot
⋅
--------------------------------------
⋅
=
Standstill torque
Rated torque
Characteristic for continuous operation
Limit characteristic at mains voltage of 400 V without field weakening
Limit characteristic with field weakening
0
10
20
30
40
50
60
M [Nm]
0
1500
3000
4500
0
1
n [rpm]