3 parameterising load adjustment, Parameterising load adjustment, 5motor interface – Lenze 9400 User Manual
Page 185: Stop

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
185
5
Motor interface
5.6
V/f control (VFCplus)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.6.1.3
Parameterising load adjustment
serves to parameterise a load adjustment in [%] proportionally to the rated torque to obtain
a correspondingly "rigid "drive behaviour even after the starting action.
• When starting torque = rated torque, a load adjustment of 50 % is suitable for most
applications.
The
parameter serves to adjust the characteristic depending on the load at CW and CCW
rotation:
Short overview: Parameters for load adjustment
Stop!
If the load adjustment is too high, the motor current may increase in idle state and the
motor may overheat!
Setting in C00961
Info
0: CW rotation in motor mode/CCW rotation in motor
mode
The motor operates in motor mode in both directions.
1: CW rotation in motor mode/CCW rotation in
generator mode
Application example: Hoist without counterweight
2: CW rotation in generator mode/CCW rotation in
motor mode
Application example: Dancer-controlled unwinder
Parameter
Info
Lenze setting
Value Unit
VFC: Load - cw/ccw-operation
CW: mot. / CCW: mot.
VFC: Load adjustment
20.00 %