C01230 | resp. to comm. task overflow, C01501 | resp. to comm. error with mxi1, C01501 – Lenze 9400 User Manual
Page 842: C01230, 14 parameter reference

14
Parameter reference
14.2
Parameter list | C01222
842
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01222
C01223
C01230
C01501
Parameter | Name:
C01222 | MEC history: Flash value
Data type: UNSIGNED_32
Index: 23353
d
= 5B39
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01223 | MEC history: Error number
Data type: UNSIGNED_32
Index: 23352
d
= 5B38
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01230 | Resp. to comm. task overflow
Data type: UNSIGNED_8
Index: 23345
d
= 5B31
h
From software version V7.0
Selection list
(Lenze setting printed in bold)
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C01501 | Resp. to comm. error with MXI1
Data type: UNSIGNED_32
Index: 23074
d
= 5A22
h
Response to communication error between "intelligent" module in module slot 1 and basic device
Selection list
(Lenze setting printed in bold)
0 No response
1 Fault
3 Quick stop by trouble
4 Warning locked
5 Warning
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1