C02542 | load reference speed, C02543 | load reference torque, C02544 | reference speed – Lenze 9400 User Manual
Page 854: C02545 | reference s-ramp time, C02547 | di_dnstate, C02547, C02542, C02543, C02545, Tting

14
Parameter reference
14.2
Parameter list | C02542
854
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02542
C02543
C02544
C02545
C02547
Parameter | Name:
C02542 | Load reference speed
Data type: UNSIGNED_32
Index: 22033
d
= 5611
h
Display range
(min. value | unit | max. value)
0.000
rpm
4294967.295
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02543 | Load reference torque
Data type: UNSIGNED_32
Index: 22032
d
= 5610
h
Display range
(min. value | unit | max. value)
0.000
Nm
4294967.295
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02544 | Reference speed
Data type: INTEGER_32
Index: 22031
d
= 560F
h
From software version V1.5
Display range
(min. value | unit | max. value)
-214748.3647
Unit/s
214748.3647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02545 | Reference S-ramp time
Data type: UNSIGNED_32
Index: 22030
d
= 560E
h
From software version V7.0
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
2147483.647 0.001 s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C02547 | DI_dnState
Data type: INTEGER_32
Index: 22028
d
= 560C
h
Bit coded status of the
.
Display range
(min. value | unit | max. value)
-2147483648
2147483647
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1