C00084 | motor stator resistance, C00085 | motor stator leakage inductance, C00087 | rated motor speed – Lenze 9400 User Manual
Page 741: C00088 | rated motor current, C00089 | rated motor frequency, C00090 | rated motor voltage, C00084, C00085, C00087, C00088

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
741
14
Parameter reference
14.2
Parameter list | C00084
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00084
C00085
C00087
C00088
C00089
C00090
Parameter | Name:
C00084 | Motor stator resistance
Data type: UNSIGNED_32
Index: 24491
d
= 5FAB
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
Ohm
125.0000 18.2200 Ohm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C00085 | Motor stator leakage inductance
Data type: UNSIGNED_32
Index: 24490
d
= 5FAA
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
mH
500.000 51.000 mH
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000
Parameter | Name:
C00087 | Rated motor speed
Data type: UNSIGNED_32
Index: 24488
d
= 5FA8
h
Setting range
(min. value | unit | max. value)
Lenze setting
50
rpm
50000 4050 rpm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C00088 | Rated motor current
Data type: UNSIGNED_32
Index: 24487
d
= 5FA7
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.01
A
1500.00 1.30 A
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100
Parameter | Name:
C00089 | Rated motor frequency
Data type: UNSIGNED_32
Index: 24486
d
= 5FA6
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.1
Hz
1000.0 270.0 Hz
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00090 | Rated motor voltage
Data type: UNSIGNED_32
Index: 24485
d
= 5FA5
h
Setting range
(min. value | unit | max. value)
Lenze setting
50
V
15000 225 V
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1