Application has started [0x006a0013, Application has stopped [0x006a0014, 0x006a0013 – Lenze 9400 User Manual
Page 638: 0x006a0014, 0x006a0015, 0x006a0012, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
638
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Pointer access in impermissible memory area [0x006a0012]
Application has started [0x006a0013]
Application has stopped [0x006a0014]
PDO mapping (MXI1): Faulty configuration [0x006a0015]
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
18
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
An invalid pointer access to a protected area occurred in
the application.
Replace application.
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
19
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The application in the controller has been started.
- (Information only)
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
20
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The application in the controller has been stopped.
- (Information only)
Module ID (decimal)
Error ID (decimal)
106: Runtime environment for IEC 61131-3 programs
21
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
CANopen communication module in MXI1: Incorrectly
configured process data mapping.
• The corresponding PDO channel is not installed, e. g.
because no communication module was selected for
module slot MXI1 in the Engineer project.
• The communication module selected for module slot
MXI1 in the Engineer project does not support PDO
mapping.
• The mapping information downloaded to the
controller is faulty.
• Integrate suitable communication module for
module slot MXI1 in the Engineer project.
• Check the configuration of the network. Then
recompile the project and transmit it to the controller.