C02701
C02702
C02703
C02704
C02705
Parameter | Name:
C02701 | Software limit positions
Data type: INTEGER_32
Index: 21874
d
= 5572
h
Basic function "
Setting range
(min. value | unit | max. value)
-214748.3647
Unit
214748.3647
Subcodes
Lenze setting
Info
C02701/1
0.0000 Unit
Positive software limit position
C02701/2
0.0000 Unit
Negative software limit position
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02702 | Limitations effective
Data type: UNSIGNED_32
Index: 21873
d
= 5571
h
Basic function "
Selection list
(Lenze setting printed in bold)
0 Deactivated
1 Activated
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1
Parameter | Name:
C02703 | Max. speed
Data type: INTEGER_32
Index: 21872
d
= 5570
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
Unit/s
214748.3647 3600.0000 Unit/s
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000
Parameter | Name:
C02704 | Max. speed [rpm]
Data type: INTEGER_32
Index: 21871
d
= 556F
h
Basic function "
Display range
(min. value | unit | max. value)
0.0
rpm
214748364.7
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C02705 | Max. acceleration
Data type: INTEGER_32
Index: 21870
d
= 556E
h
Basic function "
Setting range
(min. value | unit | max. value)
Lenze setting
0.0000
Unit/s²
214748.3647 3600.0000 Unit/s²
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10000