Required licence missing [0x008c000b, 0x008c000c, 0x008c000d – Lenze 9400 User Manual
Page 672: 0x008c000e, 0x008c000b, 13 diagnostics & fault analysis

13
Diagnostics & fault analysis
13.7
Error messages of the operating system
672
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Required licence missing [0x008c000b]
Application and device are incompatible [0x008c000c]
MXI1: Module is missing or incompatible [0x008c000d]
MXI2: Module is missing or incompatible [0x008c000e]
Module ID (decimal)
Error ID (decimal)
140: Application project manager
11
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Memory module could not be initialised.
Two possibilities:
• Use Engineer to download and activate an application
suitable for the memory module.
• Switch off controller and use memory module
suitable for the application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
12
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Application is incompatible with the controller.
• Download of an application suitable for the controller
using Engineer.
• Switch off controller and use a different memory
module with suitable application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
13
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Extension module in module slot MXI1 is incompatible
with the application.
Use extension module supported by the application.
Module ID (decimal)
Error ID (decimal)
140: Application project manager
14
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Extension module in module slot MXI2 is incompatible
with the application.
Use extension module supported by the application.