3 loading an oscillogram, Loading an oscillogram ( 592), Loading an oscillogram – Lenze 9400 User Manual
Page 592: 12 oscilloscope

12
Oscilloscope
12.5
Managing oscillograms (measured data records)
592
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.5.3
Loading an oscillogram
Configurations/data records already stored can be reloaded into the oscilloscope any time, e.g. for
the overlay function.
How to load a data record from the project:
1. Click on the
icon in the Oscilloscope toolbar.
• The Load data record dialog box appears.
2. Select the data record to be loaded from the upper list field.
3. If the data record is to be used as configuration, select the option as configuration....
4. Click Open.
• The dialog box is closed and the selected data record or the configuration is loaded.
• If the configuration to be loaded contains variables that are no longer available in the
controller, these variables are automatically removed from the configuration.
How to import a data record from a file:
1. Click on the
icon in the Oscilloscope toolbar.
• The Load data record dialog box appears.
2. Click the Search... button.
3. Select the file to be imported within the desktop environment from the Open dialog box.
4. If the data record is to be used as configuration, select the option as configuration....
5. Click Open.
• The dialog box is closed and the selected data record or the configuration is imported.
• If the configuration to be loaded contains variables that are no longer available in the
controller, these variables are automatically removed from the configuration.
Note!
The reuse of a saved configuration is only reasonable for controllers of the same type, as
otherwise due to a scaling of the oscilloscope channels that is not adapted, incorrect
values are displayed!