5 behaviour after task overflow, Behaviour after task overflow, 4drive interface – Lenze 9400 User Manual
Page 106

4
Drive interface
4.5
Behaviour after task overflow
106
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.5
Behaviour after task overflow
Up to software version V5.0 the following applies:
• After a task overflow in the application or user task the "Error" response is effected.
The following applies from software version V5.0:
• In
the error response after a task overflow in the application or user task can be
parameterised. The Lenze setting "Error" corresponds to the previous behaviour of the controller
with software versions lower than V5.0.
Tip!
For a hoist for instance the "Quick stop by trouble" error response with engagement of the
brake can be set, so that the drive is brought to standstill within the shortest time possible.
From »Engineer« version 2.10 onwards, the function block editor can also be used to
configure the behaviour of the analog and digital outputs and that of the brake control and
the output ports after a task overflow in order to adapt it to the respective application.
Configure exception handling of the outputs