C01204 | mck: feed constant, C01205 | mck: position resolution, C01206 | mck: mounting direction – Lenze 8400 User Manual
Page 995: C01206/1, C01206/2, C01204, C1204, C01205, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
995
16
Parameter reference
16.2
Parameter list | C01204
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01204
C01205
C01206
Parameter | Name:
C01204 | MCK: Feed constant
Data type: INTEGER_32
Index: 23371
d
= 5B4B
h
The feed constant corresponds to the movement of the machine during one revolution of the gearbox output shaft.
• The value is entered in application units referred to one revolution.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0001
units/rev.
214748.3647 360.0000 units/rev.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01205 | MCK: Position resolution
Data type: INTEGER_32
Index: 23370
d
= 5B4A
h
Display of the number of increments corresponding to one unit.
• 1 motor revolution ≡ 65536 increments
Display range
(min. value | unit | max. value)
0.0000
Incr./unit
214748.3647
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01206 | MCK: Mounting direction
Data type: UNSIGNED_8
Index: 23369
d
= 5B49
h
Inversion for mirrored motor and encoder mounting
Selection list
0 not inverted
1 inverted
Subcodes
Lenze setting
Info
C01206/1
0: Not inverted
Motor mounting direction
• Setting for motor mounting turned by 180°.
C01206/2
0: Not inverted
Position encoder mounting direction
• Setting for position encoder system mounting turned
by 180°.
Read access Write access CINH PLC STOP No transfer COM MOT