3 loading the oscillogram, Loading the oscillogram, Loading the oscillogram ( 626) – Lenze 8400 User Manual
Page 626: 10 oscilloscope function

10
Oscilloscope function
10.4
Managing oscillograms (measured data sets)
626
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.4.3
Loading the oscillogram
Configurations/data sets already stored can be reloaded into the oscilloscope any time, e.g. for the
overlay function.
How to load a data set from the project:
1. Click on the
icon in the Oscilloscope toolbar.
• The Load data record dialog box appears.
2. Select the data set to be loaded from the upper list field.
3. If the data record is to be used as configuration, select the option as configuration....
4. Click Open.
• The dialog box is closed and the selected data set/configuration is loaded.
• If the configuration to be loaded contains variables that are no longer available in the
controller, these variables are automatically removed from the configuration.
How to import a data set from a file:
1. Click on the
icon in the Oscilloscope toolbar.
• The Load data record dialog box appears.
2. Click the Search... button.
3. Select the file to be imported within the desktop environment from the Open dialog box.
4. If the data record is to be used as configuration, select the option as configuration....
5. Click Open.
• The dialog box is closed and the selected data set/configuration is imported.
• If the configuration to be loaded contains variables that are no longer available in the
controller, these variables are automatically removed from the configuration.
Note!
The reuse of a saved configuration is only reasonable for controllers of the same type, as
otherwise due to a scaling of the oscilloscope channels that is not adapted, incorrect