C00234 | oscillation damping influence, C00235 | oscillation damping filter time, C00236 | field weakening oscillation damping – Lenze 8400 User Manual
Page 795: C00241 | l_nset_1: hyst. nset reached, C00234, C00236, Is increased, th, N damping, C00235, Shou

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
795
16
Parameter reference
16.2
Parameter list | C00234
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00234
C00235
C00236
C00241
Parameter | Name:
C00234 | Oscillation damping influence
Data type: UNSIGNED_16
Index: 24341
d
= 5F15
h
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
250.00 5.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00235 | Oscillation damping filter time
Data type: UNSIGNED_8
Index: 24340
d
= 5F14
h
Setting range
(min. value | unit | max. value)
Lenze setting
2
ms
250 32 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00236 | Field weakening oscillation damping
Data type: UNSIGNED_8
Index: 24339
d
= 5F13
h
Oscillation damping for idling machines
Setting range
(min. value | unit | max. value)
Lenze setting
0
40 14
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00241 | L_NSet_1: Hyst. NSet reached
Data type: INTEGER_16
Index: 24334
d
= 5F0E
h
FB: Hysteresis window for the zero detection of the speed output setpoint
• The speed threshold for the zero detection is 1 %
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 0.50 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100