13 ls_keypad, 13 ls_keypad 2, Ls_keypad – Lenze 8400 User Manual
Page 1442: 18 function library

18
Function library
18.2
System blocks | LS_Keypad
1442
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.2.13
LS_Keypad
This system block is used on I/O interconnection level if the "Keypad" control mode has been
In the "Keypad" control mode, the LS_Keypad system block passes on various setpoints and control
commands to the technology application which can be selected/activated via codes using the
keypad.
Outputs
Identifier
Data type
Value/meaning
bSetQuickstop
BOOL
= "1" ≡ Request quick stop
bSetDCBrake
BOOL
= "1" ≡ Request DC-injection braking
nTorqueMotLim
INT
Torque limit in motor mode set in
• Lenze setting: 100.00 %
nTorqueGenLim
INT
Torque limit in generator mode set in
• Lenze setting: 100.00 %
bSetSpeedCcw
BOOL
= "1" ≡ Request reversal
nMainSetValue
INT
Setpoint speed set in
• Lenze setting: 0.00 %
bJogSpeed1
BOOL
= "1" ≡ Request fixed speed setpoint 1
bJogSpeed2
BOOL
= "1" ≡ Request fixed speed setpoint 2
bMPotEnable
BOOL
= "1" ≡ Motor potentiometer: Request activation
bMPotUp
BOOL
= "1" ≡ Motor potentiometer: Request positive acceleration
bMPotDown
BOOL
= "1" ≡ Motor potentiometer: Request negative acceleration
E6HW4XLFNVWRS
E6HW'&%UDNH
Q7RUTXH0RW/LP
Q7RUTXH*HQ/LP
E6HW6SHHG&FZ
Q0DLQ6HW9DOXH
E-RJ6SHHG
E-RJ6SHHG
&
&
&
&
&
&
&
&
E03RW(QDEOH
E03RW8S
E03RW'RZQ
&
&
&
/6B.H\SDG