C01065 | l_switchpoint_1: running time, C01066 | l_switchpoint_1: status, C01067 | inversion of gearbox stages – Lenze 8400 User Manual
Page 976: C01067/1, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C01065
976
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01065
C01066
C01067
Parameter | Name:
C01065 | L_SwitchPoint_1: Running time
Data type: UNSIGNED_16
Index: 23510
d
= 5BD6
h
From version 12.00.00
Setting range
(min. value | unit | max. value)
0
ms
60000
Subcodes
Lenze setting
Info
C01065/1
0 ms
: Running time 1
C01065/2
0 ms
: Running time 2
C01065/3
0 ms
: Running time 3
C01065/4
0 ms
: Running time 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01066 | L_SwitchPoint_1: Status
Data type: INTEGER_16
Index: 23509
d
= 5BD5
h
From version 12.00.00
Selection list
0 OK
10 FB not active
100 Switching points not plausible
Subcodes
Info
C01066/1
: Status 1
C01066/2
: Status 2
C01066/3
: Status 3
C01066/4
: Status 4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01067 | Inversion of gearbox stages
Data type: UNSIGNED_8
Index: 23508
d
= 5BD4
h
From version 12.00.00
Selection list
0 not inverted
1 inverted
2 Automatically from MCK
Subcodes
Lenze setting
Info
C01067/1
0: Not inverted
: Invert. gearbox nSet_v
C01067/2
0: Not inverted
: Invert. gearbox nSet_v
C01067/3
0: Not inverted
: Invert. gearbox nMotorSpeedAct_v
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1