3commissioning – Lenze 8400 User Manual
Page 78

3
Commissioning
3.9
Commissioning of the "Switch-off positioning" technology application
78
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.9
Commissioning of the "Switch-off positioning" technology application
[3-3]
Block diagram for wiring of the commissioning example for the "Switch-off positioning" application
Note!
Take all the necessary safety precautions before you carry out the following
commissioning steps and switch the device on!
Safety instructions with regard to commissioning
System constellation
X41/DI1
Initiator connection for stop function 1
X41/DI2
Initiator connection for stop function 2
X42/DI3
Quick stop for CW rotation / selection of switch-off position 1
X42/DI4
Quick stop for CCW rotation / selection of switch-off position 2
X70
Diagnostic interface for connecting the USB diagnostic adapter
8400 protec
X61
X6
DIAG
AR A1U GA
X50
24O DI1 DI2 GIO
X41
24O DI3 DI4 GIO
X42
24O DI5 DI6 GIO
X43
U
V W
X70
t [s]
0
1
QSP
Cw
Ccw
-
DI1
DI2
DI1
DI2
v [m/s]
C00039/2
C00012
C00012
C00013
C00039/2
C00013
Cw
Ccw
Cw
Ccw
M
3~
i
0
1
0
0
1
1