C01084 | ls_writeparamlist: error line, C01085 | ls_writeparamlist: index, C01086 | ls_writeparamlist: writevalue_1 – Lenze 8400 User Manual
Page 982: C01087 | ls_writeparamlist: writevalue_2, C01084, C01085/1 ... n, C01085/1, C01085/2, C01085/3, C01085/4 ... n

16
Parameter reference
16.2
Parameter list | C01084
982
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01084
C01085
C01086
C01087
Parameter | Name:
C01084 | LS_WriteParamList: Error line
Data type: UNSIGNED_8
Index: 23491
d
= 5BC3
h
: Display of the number of list entry where the error occurred (in connection with the value
set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range
(min. value | unit | max. value)
0
32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01085 | LS_WriteParamList: Index
Data type: INTEGER_32
Index: 23490
d
= 5BC2
h
: Parameter for entry 1 ... 32
Setting range
(min. value | unit | max. value)
0.000
16000.000
Subcodes
Lenze setting
Info
C01085/1
0.000
Parameter for entries 1 ... 32
• Format: .
• Examples: "12.000" = C00012; "26.001" = C00026/1
C01085/...
C01085/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01086 | LS_WriteParamList: WriteValue_1
Data type: INTEGER_32
Index: 23489
d
= 5BC1
h
: Parameter values - value set 1
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01086/1
0
Parameter values - value set 1
• Parameter values for the parameters defined in
/1 ... 32.
C01086/...
C01086/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01087 | LS_WriteParamList: WriteValue_2
Data type: INTEGER_32
Index: 23488
d
= 5BC0
h
: Parameter values - value set 2
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01087/1
0
Parameter values - value set 2
• Parameter values for the parameters defined in
/1 ... 32.
C01087/...
C01087/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1