Function library
18.1
Function blocks | L_NSet_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter
wState
WORD
Bit-coded status word
• Bits that are not listed are reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
nSetValue_a
INT
Speed-setpoint input signal of the ramp function generator
• Scaling: 16384 ≡ 100 %
Parameter
Possible settings
Info
0.000
s
999.900 Acceleration time T
ir
for the main
setpoint
• Lenze setting: 0.000 s
0.000
s
999.900 Deceleration time T
if
for the main
setpoint
• Lenze setting: 0.000 s
-199.99
%
199.99 Fixed setpoints (JOG setpoints)
• Lenze setting: 0.00 %
0.000
s
999.900 Alternative acceleration times (T
ir
)
for the main setpoint
• Lenze setting: 0.000 s
0.000
s
999.900 Alternative deceleration times (T
if
)
for the main setpoint
• Lenze setting: 0.000 s
Activates ramp rounding with PT1
behaviour for the main setpoint
• The corresponding S-ramp time
• Lenze setting: 0 (deactivated)
0 Off
1 PT1 behaviour
0.01
s
50.00 S-ramp time PT1
• Lenze setting: 20.00 s
Selection of the arithmetic function
for combining main and additional
setpoint
0 NOut = NSet
Lenze setting
• The additional setpoint is not
processed.
1 NOut = NSet + NAdd
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 NOut = (NSet * 100%) / (100% -
NAdd)
0.000
s
999.900 Acceleration time T
ir
for the
additional setpoint
• Lenze setting: 0.000 s
Identifier
Data type
Value/meaning