C00051 | mctrl: actual speed value, C00052 | motor voltage, C00053 | dc-bus voltage – Lenze 8400 User Manual
Page 753: C00054 | motor current, C00051, C00053, C00054, E (display in, As well as th, C00052

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
753
16
Parameter reference
16.2
Parameter list | C00051
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00051
C00052
C00053
C00054
Parameter | Name:
C00051 | MCTRL: Actual speed value
Data type: INTEGER_32
Index: 24524
d
= 5FCC
h
Display of the actual speed value of the motor shaft
Note:
The displayed value only corresponds to the real actual speed value of the motor shaft if an encoder is connected to
the motor and the evaluation of the feedback signal has been set correctly ("Closed loop" operation).
In case of operation without speed feedback, the signal is calculated from the motor control and thus may not
correspond to the real actual speed.
Display range
(min. value | unit | max. value)
-60000
rpm
60000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00052 | Motor voltage
Data type: UNSIGNED_16
Index: 24523
d
= 5FCB
h
Display of the current motor voltage/output voltage of the inverter
Display range
(min. value | unit | max. value)
0
V
1000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00053 | DC-bus voltage
Data type: UNSIGNED_16
Index: 24522
d
= 5FCA
h
Display of the current DC-bus voltage
Display range
(min. value | unit | max. value)
0
V
1000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00054 | Motor current
Data type: UNSIGNED_16
Index: 24521
d
= 5FC9
h
Display of the current motor current/output current of the inverter
Display range
(min. value | unit | max. value)
0.00
A
300.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100