beautypg.com

C02292/1, C02292/2, C02292/3 – Lenze 8400 User Manual

Page 1044: C02292/4, C02293/1, C02293/2, C02293/3, C02293/4, C02294/1, C02294/2

background image

16

Parameter reference

16.2

Parameter list | C02292

1044

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02292

C02293

C02294

Parameter | Name:

C02292 | LS_WriteParamList: SLVC: Cross current controller gain

Data type: INTEGER_16

Index: 22283

d

= 570B

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.00

%

20.00

Subcodes

Lenze setting

Info

C02292/1

0.00 %

LS_WriteParamList

: c986_val1

C02292/2

0.00 %

LS_WriteParamList

: c986_val2

C02292/3

0.00 %

LS_WriteParamList

: c986_val3

C02292/4

0.00 %

LS_WriteParamList

: c986_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C02293 | LS_WriteParamList: Inverter motor brake: nAdd

Data type: INTEGER_16

Index: 22282

d

= 570A

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0

rpm

1000

Subcodes

Lenze setting

Info

C02293/1

80 rpm

LS_WriteParamList

: c987_val1

C02293/2

80 rpm

LS_WriteParamList

: c987_val2

C02293/3

80 rpm

LS_WriteParamList

: c987_val3

C02293/4

80 rpm

LS_WriteParamList

: c987_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02294 | LS_WriteParamList: Inverter motor brake: PT1 filter time

Data type: INTEGER_16

Index: 22281

d

= 5709

h

From version 12.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Setting range

(min. value | unit | max. value)

0.0

ms

100.0

Subcodes

Lenze setting

Info

C02294/1

0.0 ms

LS_WriteParamList

: c988_val1

C02294/2

0.0 ms

LS_WriteParamList

: c988_val2

C02294/3

0.0 ms

LS_WriteParamList

: c988_val3

C02294/4

0.0 ms

LS_WriteParamList

: c988_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10