C02292/1, C02292/2, C02292/3 – Lenze 8400 User Manual
Page 1044: C02292/4, C02293/1, C02293/2, C02293/3, C02293/4, C02294/1, C02294/2
16
Parameter reference
16.2
Parameter list | C02292
1044
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02292
C02293
C02294
Parameter | Name:
C02292 | LS_WriteParamList: SLVC: Cross current controller gain
Data type: INTEGER_16
Index: 22283
d
= 570B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
%
20.00
Subcodes
Lenze setting
Info
C02292/1
0.00 %
: c986_val1
C02292/2
0.00 %
: c986_val2
C02292/3
0.00 %
: c986_val3
C02292/4
0.00 %
: c986_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C02293 | LS_WriteParamList: Inverter motor brake: nAdd
Data type: INTEGER_16
Index: 22282
d
= 570A
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
rpm
1000
Subcodes
Lenze setting
Info
C02293/1
80 rpm
: c987_val1
C02293/2
80 rpm
: c987_val2
C02293/3
80 rpm
: c987_val3
C02293/4
80 rpm
: c987_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02294 | LS_WriteParamList: Inverter motor brake: PT1 filter time
Data type: INTEGER_16
Index: 22281
d
= 5709
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.0
ms
100.0
Subcodes
Lenze setting
Info
C02294/1
0.0 ms
: c988_val1
C02294/2
0.0 ms
: c988_val2
C02294/3
0.0 ms
: c988_val3
C02294/4
0.0 ms
: c988_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10