C02210 | ls_writeparamlist: motor control, C02213 | ls_writeparamlist: vfc: vmin boost, Des from code – Lenze 8400 User Manual
Page 1022: C02210, C02210/1, C02210/2, C02210/3, C02210/4, C02212/1, C02212/2

16
Parameter reference
16.2
Parameter list | C02210
1022
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02210
C02212
C02213
Parameter | Name:
C02210 | LS_WriteParamList: Motor control
Data type: UNSIGNED_8
Index: 22365
d
= 575D
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Selection list
2 SC: Servo control ASM
3 SLPSM: Sensorless PSM
4 SLVC: Vector control
6 VFCplus: V/f linear
7 VFCplus: V/f linear + encoder
8 VFCplus: V/f quadr
9 VFCplus: V/f quadr + encoder
10 VFCplus: V/f definable
11 VFCplusEco: V/f energy-saving
Subcodes
Lenze setting
Info
C02210/1
6: VFCplus: V/f linear
: c6_val1
C02210/2
6: VFCplus: V/f linear
: c6_val2
C02210/3
6: VFCplus: V/f linear
: c6_val3
C02210/4
6: VFCplus: V/f linear
: c6_val3
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02212 | LS_WriteParamList: VFC: V/f base frequency
Data type: UNSIGNED_16
Index: 22363
d
= 575B
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
7.5
Hz
2600.0
Subcodes
Lenze setting
Info
C02212/1
50.0 Hz
: c15_val1
C02212/2
50.0 Hz
: c15_val2
C02212/3
50.0 Hz
: c15_val3
C02212/4
50.0 Hz
: c15_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10
Parameter | Name:
C02213 | LS_WriteParamList: VFC: Vmin boost
Data type: UNSIGNED_16
Index: 22362
d
= 575A
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0.00
%
100.00
Subcodes
Lenze setting
Info
C02213/1
1.60 %
: c16_val1
C02213/2
1.60 %
: c16_val2
C02213/3
1.60 %
: c16_val3
C02213/4
1.60 %
: c16_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100