Basic drive functions (MCK)
8.8
Positioning
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
8.8.2.2
Profile entry
In the »Engineer«, the following parameterisation dialog is available for setting the profile
parameters:
A profile is described by the following profile parameters:
Icon
Profile parameter
(Standard) profile
Profile data set (profile numbers 1 ... 15), in which the profile data are stored.
Mode (
)
Selection of the way in which positioning is to be carried out.
Position (
)
Target position or distance to be traversed.
When the position is indicated, a distinction is made between absolute position and relative position:
• An absolute position always indicates the distance to the defined zero position:
Absolute position = Target position
• A relative position indicates the distance to the starting position (current position):
Relative position = Target position - Starting position
A
10
20
30
40
50
60
70
80
90
100
10
30
80
P1
P2
P3
0
10
20
30
40
50
60
70
80
90
100
10
20
50
P3
P2
P1
0