beautypg.com

C00469 | keypad: fct. stop key, C00470 | ls_parfree_b, C00471 | ls_parfree – Lenze 8400 User Manual

Page 834: C00469, 16 parameter reference

background image

16

Parameter reference

16.2

Parameter list | C00469

834

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00469

C00470

C00471

Parameter | Name:

C00469 | Keypad: Fct. STOP key

Data type: INTEGER_32

Index: 24106

d

= 5E2A

h

Selection of the function for the STOP key on the keypad
Selection list

(Lenze setting printed in bold)

Info

0 No response

STOP key does not have any function

1 Inhibit controller

STOP key sets controller inhibit in the drive

2 Activate quick stop

STOP key sets quick stop in the drive

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00470 | LS_ParFree_b

Data type: UNSIGNED_8

Index: 24105

d

= 5E29

h

The

LS_ParFree_b

SB: Setting of the signal level to be output

Selection list

0 False
1 True

Subcodes

Lenze setting

Info

C00470/1

0: FALSE

Signal level for output bPar1 ... bPar32

C00470/...
C00470/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00471 | LS_ParFree

Data type: UNSIGNED_16

Index: 24104

d

= 5E28

h

The

LS_ParFree

SB: Setting of the words to be output

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Bit0

... ...

Bit 15 Bit15

Subcodes

Lenze setting

Info

C00471/1

0x0000

Value for output wPar1 ... wPar32

C00471/...
C00471/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT