C00469
C00470
C00471
Parameter | Name:
C00469 | Keypad: Fct. STOP key
Data type: INTEGER_32
Index: 24106
d
= 5E2A
h
Selection of the function for the STOP key on the keypad
Selection list
(Lenze setting printed in bold)
Info
0 No response
STOP key does not have any function
1 Inhibit controller
STOP key sets controller inhibit in the drive
2 Activate quick stop
STOP key sets quick stop in the drive
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00470 | LS_ParFree_b
Data type: UNSIGNED_8
Index: 24105
d
= 5E29
h
SB: Setting of the signal level to be output
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00470/1
0: FALSE
Signal level for output bPar1 ... bPar32
C00470/...
C00470/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00471 | LS_ParFree
Data type: UNSIGNED_16
Index: 24104
d
= 5E28
h
SB: Setting of the words to be output
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Bit0
... ...
Bit 15 Bit15
Subcodes
Lenze setting
Info
C00471/1
0x0000
Value for output wPar1 ... wPar32
C00471/...
C00471/32
Read access Write access CINH PLC STOP No transfer COM MOT