1069
16
Parameter reference
16.2
Parameter list | C02874
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02874
C02875
Parameter | Name:
C02874 | PLI without motion
Data type: UNSIGNED_16
Index: 21701
d
= 54C5
h
From version 12.00.00
Pole position identification without motion
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 for SLPSM with controller enable
Bit 1 for SC PSM with mains on
Bit 2 for SC PSM with controller enable
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Subcodes
Lenze setting
Info
C02874/1
0x0001
PLI without motion
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02875 | PLI without motion: Adaptation of ident angle
Data type: INTEGER_8
Index: 21700
d
= 54C4
h
From version 12.00.00
Pole position identification without motion
Setting range
(min. value | unit | max. value)
-100
°
100
Subcodes
Lenze setting
Info
C02875/1
0 °
PLI without motion: Adaptation of ident angle
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1