2 saving the oscillogram, Saving the oscillogram, Saving the oscillogram ( 625) – Lenze 8400 User Manual
Page 625: 10 oscilloscope function

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
625
10
Oscilloscope function
10.4
Managing oscillograms (measured data sets)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.4.2
Saving the oscillogram
After the variables to be recorded have been selected and the required settings have been entered,
you can save the configuration and recording, if already executed, for future use in the project or
export them to a file.
How to save the data set in the project:
1. Click on the
icon in the Oscilloscope toolbar.
• The Save data record dialog box appears.
2. Enter a name in the Name of the data record to be stored input field.
3. Click Filing in the project.
• The dialog box is closed and the current data set is filed in the project.
How to export the data set to a file:
1. Click on the
icon in the Oscilloscope toolbar.
• The Save data record dialog box appears.
2. Enter a name in the Name of the data record to be stored input field.
3. Click the Export to file button.
4. Specify the data record to be stored and the filing folder in the Save as dialog box.
5. Click Save.
• The dialog box is closed and the current data set is saved.
Note!
The reuse of a saved configuration is only reasonable for controllers of the same type, as
otherwise due to a scaling of the oscilloscope channels that is not adapted, incorrect
values are displayed!
Note!
The data set is only saved if the entire project is saved!