162 l_smstatedecoderio_1, 162 l_smstatedecoderio_1 8, L_smstatedecoderio_1 – Lenze 8400 User Manual
Page 1408: Wiostat, 18 function library

18
Function library
18.1
Function blocks | L_SMStateDecoderIO_1
1408
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.1.162
L_SMStateDecoderIO_1
The integrated safety system transmits the status of safety functions to the application via the bit
coded wIOState status signal of the SB LS_SMInterface. This FB decodes the status signal into
individual boolean status signals for further use in the function block interconnection.
• The functionality of this FB corresponds to a converter "WORDBOOL", but the outputs of this
FB are named according to their meaning.
Inputs
Outputs
Identifier
Data type
Information/possible settings
wIOState
WORD
Input for the bit coded I/O status signal of the integrated safety system
• The I/O status signal of the integrated safety system is provided at the wIOState
output of the
system block.
Bit*
Identifier
Meaning in case of TRUE
0 bSafeDigIn1
Sensor input 1 in ON state.
1 bSafeDigIn2
Sensor input 2 in ON state.
5 bACKInputStop
Restart acknowledgement via terminal is done (if TRUEFALSE).
6 bACKInputError
Error acknowledgement via terminal is done (if TRUEFALSE).
8 bPROFISafeAIS
Restart acknowledgement via safety bus is done (if FALSETRUE).
9 bPROFISafeAIE
Error acknowledgement via safety bus is done (if FALSETRUE).
* With regard to the wIOState input signal.
/B606WDWH'HFRGHU,2B
E6DIH'LJ,Q
Z,26WDWH
%LW
%LW
%LW
%LW
%LW
:25'
E6DIH'LJ,Q
E$&.,QSXW6WRS
E$&.,QSXW(UURU
E352),6DIH$,6
E352),6DIH$,(
%LW