C00828 | l_digitallogic_3: function, C00829 | l_digitallogic_3: truth table, C00830 | 16-bit inputs – Lenze 8400 User Manual
Page 904: C00830/29, C00830/28, C00830/26, C00830/32, C00830/22, C00830/31, C00830/4
16
Parameter reference
16.2
Parameter list | C00828
904
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00828
C00829
C00830
Parameter | Name:
C00828 | L_DigitalLogic_3: Function
Data type: UNSIGNED_8
Index: 23747
d
= 5CC3
h
From version 12.00.00
FB: Selection of the internal logic function
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND bIn2 AND bIn3
AND operation
3 bOut = bIn1 OR bIn2 OR bIn3
OR operation
4 bOut = f (truth table)
The truth table parameterised in
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00829 | L_DigitalLogic_3: Truth table
Data type: UNSIGNED_8
Index: 23746
d
= 5CC2
h
From version 12.00.00
FB: Parameterisation of the truth table
Selection list
0 False
1 True
Subcodes
Lenze setting
Info
C00829/1
0: FALSE
: bIn3...bIn1=0 0 0
C00829/2
0: FALSE
: bIn3...bIn1=0 0 1
C00829/3
0: FALSE
: bIn3...bIn1=0 1 0
C00829/4
0: FALSE
: bIn3...bIn1=0 1 1
C00829/5
0: FALSE
: bIn3...bIn1=1 0 0
C00829/6
0: FALSE
: bIn3...bIn1=1 0 1
C00829/7
0: FALSE
: bIn3...bIn1=1 1 0
C00829/8
0: FALSE
: bIn3...bIn1=1 1 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00830 | 16-bit inputs [%]
Data type: INTEGER_16
Index: 23745
d
= 5CC1
h
Display in percent of 16-bit input values of different blocks
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Info
C00830/1
: nIn_a
C00830/2
: nIn1_a
C00830/3
: nIn2_a
C00830/4
: nIn3_a
C00830/5
: nIn_a
C00830/6
: nOffset_a
C00830/7
: nGain_a