C00364 | can messageerror, C00366 | number of can sdo channels, T in – Lenze 8400 User Manual
Page 815: C00366, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
815
16
Parameter reference
16.2
Parameter list | C00364
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00364
C00366
Parameter | Name:
C00364 | CAN MessageError
Data type: UNSIGNED_8
Index: 24211
d
= 5E93
h
Selection list
(read only)
0 No Error
1 StuffError
2 FormError
3 AckError
4 Bit1Error
5 Bit0Error
6 CRCError
7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00366 | Number of CAN SDO channels
Data type: UNSIGNED_8
Index: 24209
d
= 5E91
h
Selection of the number of active parameter data channels
• In the Lenze setting, according to CANopen only parameter data channel 1 is activated.
• To activate both parameter data channels, set the selection "2 SDO Lenze".
Selection list
(Lenze setting printed in bold)
0 1 SDO CANOpen
1 2 SDO Lenze
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1