C01224 | mck: ref. speeds, C01225 | mck: ref. accelerations, C01226 | mck: ref. s-ramp time – Lenze 8400 User Manual
Page 1000: C01226/1, C01224/1, C01225/1, C01224/2, C01225/2, 16 parameter reference

16
Parameter reference
16.2
Parameter list | C01224
1000
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01224
C01225
C01226
Parameter | Name:
C01224 | MCK: Ref. speeds
Data type: INTEGER_32
Index: 23351
d
= 5B37
h
Speeds for reference search/homing
Setting range
(min. value | unit | max. value)
0.0000
unit/s
214748.3647
Subcodes
Lenze setting
Info
C01224/1
720.0000 unit/s
MCK: Ref. initial speed
• Starting speed for approaching the pre-stop signals.
C01224/2
180.0000 unit/s
MCK: Ref. search speed
• Search speed for detecting the reference initiator.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01225 | MCK: Ref. accelerations
Data type: INTEGER_32
Index: 23350
d
= 5B36
h
Accelerations for reference search/homing
Setting range
(min. value | unit | max. value)
0.0000
unit/s2
214748.3647
Subcodes
Lenze setting
Info
C01225/1
720.0000 unit/s2
MCK: Ref. initial acceleration
• Starting acceleration for the starting speed ramps.
C01225/2
720.0000 unit/s2
MCK: Ref. search acceleration
• Search acceleration for the search speed ramps.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000
Parameter | Name:
C01226 | MCK: Ref. S-ramp time
Data type: UNSIGNED_16
Index: 23349
d
= 5B35
h
S-ramp time for reference search/homing
• Setting "0 s" ≡ no rounding
Setting range
(min. value | unit | max. value)
0.000
s
10.000
Subcodes
Lenze setting
Info
C01226/1
0.000 s
MCK: Ref. S-ramp time
• S-ramp time for the starting and search speed ramps.
Read access Write access CINH PLC STOP No transfer COM MOT