C01141 | l_transient 5-8 pulse duration, C01150 | l_phaseintk: function, C01151 | l_phaseintk: compare – Lenze 8400 User Manual
Page 993: 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
993
16
Parameter reference
16.2
Parameter list | C01141
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01141
C01150
C01151
Parameter | Name:
C01141 | L_Transient 5-8 pulse duration
Data type: UNSIGNED_16
Index: 23434
d
= 5B8A
h
Setting range
(min. value | unit | max. value)
0.000
s
60.000
Subcodes
Lenze setting
Info
C01141/1
0.000 s
: Pulse duration
C01141/2
0.000 s
: Pulse duration
C01141/3
0.000 s
: Pulse duration
C01141/4
0.000 s
: Pulse duration
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01150 | L_PhaseIntK: Function
Data type: UNSIGNED_8
Index: 23425
d
= 5B81
h
Loading behaviour of the integrator
Selection list
Info
0 Loading with level
Load integrator with TRUE level at the input bLoad
1 Loading with edge
Load integrator with FALSE/TRUE edge at the input
bLoad
2 Loading with level + reset
Load integrator when the comparison value (
) is
reached or with TRUE level at the bLoad input
Subcodes
Lenze setting
Info
C01150/1
0: Loading with level
: Function
C01150/2
0: Loading with level
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01151 | L_PhaseIntK: Compare
Data type: INTEGER_32
Index: 23424
d
= 5B80
h
Comparison value
Setting range
(min. value | unit | max. value)
0
2147418112
Subcodes
Lenze setting
Info
C01151/1
0
: Comparison value
C01151/2
0
: Comparison value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1