C00101 | add. accel. time x, C00103 | add. decel. time x, C00101/1 – Lenze 8400 User Manual
Page 763: C00103/1, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
763
16
Parameter reference
16.2
Parameter list | C00101
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00101
C00103
Parameter | Name:
C00101 | Add. accel. time x
Data type: UNSIGNED_32
Index: 24474
d
= 5F9A
h
: FB: Additional acceleration times for the main setpoint
• The additional acceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the
FB.
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00101/1
0.000 s
Add. accel. time 1 ... 15
C00101/...
C00101/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00103 | Add. decel. time x
Data type: UNSIGNED_32
Index: 24472
d
= 5F98
h
FB: Additional deceleration times for the main setpoint
• The additional deceleration times set here can be selected via the binary inputs bTI1 ... bTI8 of the
FB.
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00103/1
0.000 s
Add. decel. time 1 ... 15
C00103/...
C00103/15
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000