C02312 | ls_writeparamlist: pli without motion, C02312/1, C02312/2 – Lenze 8400 User Manual
Page 1051: C02312/3, C02312/4, C02313/1, C02313/2, C02313/3, C02313/4, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1051
16
Parameter reference
16.2
Parameter list | C02312
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02312
C02313
Parameter | Name:
C02312 | LS_WriteParamList: PLI without motion
Data type: UNSIGNED_16
Index: 22263
d
= 56F7
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 for SLPSM with controller enable
Bit 1 for SC PSM with mains on
Bit 2 for SC PSM with controller enable
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Subcodes
Lenze setting
Info
C02312/1
0x0001
: c2874_s1_val1
C02312/2
0x0001
: c2874_s1_val2
C02312/3
0x0001
: c2874_s1_val3
C02312/4
0x0001
: c2874_s1_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02313 | LS_WriteParamList: PLI without motion: Adaptation of ident angle
Data type: INTEGER_8
Index: 22262
d
= 56F6
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
-100
°
100
Subcodes
Lenze setting
Info
C02313/1
0 °
: c2875_s1_val1
C02313/2
0 °
: c2875_s1_val2
C02313/3
0 °
: c2875_s1_val3
C02313/4
0 °
: c2875_s1_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1