_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00134
C00136
Parameter | Name:
C00134 | L_NSet_1: Ramp smoothing
Data type: UNSIGNED_8
Index: 24441
d
= 5F79
h
FB: Configuration of the ramp rounding for the main setpoint
Selection list
(Lenze setting printed in bold)
Info
0 Off
Ramp rounding deactivated
1 PT1 behaviour
Ramp rounding with PT1 behaviour
• The corresponding S-ramp time must be set in
.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00136 | Communication control words
Data type: UNSIGNED_16
Index: 24439
d
= 5F77
h
Control words of the communication interfaces
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 SwitchOn
Bit 1 DisableVoltage
Bit 2 SetQuickStop
Bit 3 EnableOperation
Bit 4 ModeSpecific_1
Bit 5 ModeSpecific_2
Bit 6 ModeSpecific_3
Bit 7 ResetFault
Bit 8 SetHalt
Bit 9 Reserved_1
Bit 10 Reserved_2
Bit 11 LenzeSpecific_1
Bit 12 LenzeSpecific_2
Bit 13 LenzeSpecific_3
Bit 14 SetFail
Bit 15 LenzeSpecific_4
Subcodes
Info
C00136/1
MCI control word
• Control word of the MCI communication interface
(communication module)
C00136/2
CAN control word
• Control word of the CAN communication interface
(X31/X32)
Read access Write access CINH PLC STOP No transfer COM MOT