18.1.133

L_PCTRL_1

This FB is a PID controller and can be used for various control tasks (e.g. as dancer position controller,

tension controller, or pressure controller).
The FB is provided with the following functions:

• Adjustable control algorithm (P, PI, PID)
• Ramp function generator for preventing setpoint step-changes at the input
• Limitation of the controller output
• Factorisation of the output signal
• Vp adaptation
• Integral action component can be switched off
• Comparison function "Actual value = setpoint"

Inputs

Identifier

Data type

Information/possible settings

nAdapt_a

INT

Adaptation of gain Vp set in

C00222

in percent

• Internal limitation to ± 199.99 %

• Changes can be done online.

• Display parameter:

C00830/62

nNset_a

INT

Speed setpoint

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.99 %

• Display parameter:

C00830/89

nSet_a

INT

Sensor and process setpoint for operating modes 2, 4 and 5

• Scaling: 16384 ≡ 100 %

• Internal limitation to ± 199.99 %

• Display parameter:

C00830/63