C01031 | l_curve_3: input limitation, C01033 | l_curve_3: table x-values, C01034 | l_curve_3: table y-values – Lenze 8400 User Manual
Page 968: 16 parameter reference
16
Parameter reference
16.2
Parameter list | C01031
968
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01031
C01033
C01034
Parameter | Name:
C01031 | L_Curve_3: Input limitation
Data type: INTEGER_16
Index: 23544
d
= 5BF8
h
From version 12.00.00
FB
: Upper and lower limit for input value
Setting range
(min. value | unit | max. value)
-199.99
%
199.99
Subcodes
Lenze setting
Info
C01031/1
199.99 %
: Max. input
C01031/2
-199.99 %
: Min. input
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C01033 | L_Curve_3: Table X-values
Data type: INTEGER_16
Index: 23542
d
= 5BF6
h
From version 12.00.00
FB
: X-values for characteristic function
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01033/1
0
X values 1 ... 32 for characteristic function
C01033/...
C01033/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01034 | L_Curve_3: Table Y-values
Data type: INTEGER_16
Index: 23541
d
= 5BF5
h
From version 12.00.00
FB
: Y-value for characteristic function
Setting range
(min. value | unit | max. value)
-32767
32767
Subcodes
Lenze setting
Info
C01034/1
0
Y values 1 ... 32 for characteristic function
C01034/...
C01034/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1