4 manual jog, Manual jog, 3commissioning – Lenze 8400 User Manual
Page 92
3
Commissioning
3.10
PC manual control
92
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.10.4
Manual jog
In the "Manual jog" mode, the drive can be traversed manually in a clockwise or counter-clockwise
direction.
The change to the "Manual jog" mode can be made by selecting the correspondent option on the
Positioning tab:
• The profile parameters saved in the parameter set for the basic "manual control" function are
used:
How to traverse the drive manually in inching mode:
1. If the controller is still inhibited, enable the controller via the Enable controller button.
• Please note that the controller is only enabled if no other sources of a controller inhibit
(e.g. terminal RFR) are active.
If the controller is in the "OperationEnabled" status:
2. Click << Left or Right >> (and keep it pressed) to traverse the drive in the corresponding
direction of rotation.
You can find detailed information on the "Manual jog" mode in the chapter entitled
"Basic drive functions" in the subchapter "
Parameter
Lenze setting
Info
Value Unit
Speed 1
(
360.0000 units/s
Speed for manual jog
Acceleration
(
720.0000 units/s
2
For accelerating and decelerating, different values can
be set so that smooth starting and quick stopping of the
drive can be implemented.
Delay
(
720.0000 units/s
2
S-ramp time
(
0.000 s
In order to reduce jerking, the two ramps can be set in
such a way that they are s-shaped. This is done by
entering a relative S-ramp time.