4 parameters with subcodes, 4 parameter attributes, Parameters with subcodes – Lenze 8400 User Manual
Page 736: Parameter attributes, 16 parameter reference

16
Parameter reference
16.1
Structure of the parameter descriptions
736
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16.1.3.4
Parameters with subcodes
Description structure
Parameter setting in the »Engineer«
The »Engineer« parameter list displays each subcode individually. The parameters are set as
described in the previous chapters.
16.1.4
Parameter attributes
The table footers contain the parameter attributes:
Parameter | Name:
Cxxxxx | _____________
Data type: _______
Index: _______
Description
Setting range
(min. value | unit | max. value)
Subcodes
Lenze setting
Cxxxxx/1
Cxxxxx/2
Cxxxxx/3
Cxxxxx/4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Attribute
Meaning
Read access
Read access to parameter possible.
Write access
Write access to parameter possible.
• Please also observe the following attributes:
CINH
Parameter value can only be changed when the controller is
inhibited.
PLC STOP
Parameter value can only be changed when the application is
stopped.
No transfer
Parameter is not transferred to controller when the command Download parameter set is
executed.
COM
Communication-relevant parameter
• This parameter is relevant for parameter data transfer via the (CAN) system bus.
MOT
Motor control parameters