beautypg.com

10 maximum torque monitoring, 11 motor speed monitoring, Motor speed monitoring – Lenze 8400 User Manual

Page 292: Maximum torque monitoring, 5motor control (mctrl)

background image

5

Motor control (MCTRL)

5.14

Monitoring

292

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.14.10

Maximum torque monitoring

If the maximum possible torque

C00057

is reached at the motor shaft, the response set in

C00608

will be carried out (Lenze setting: "0: No Reaction").
If the activated monitoring is tripped:

• The "

ot1: Maximum torque reached

" error message is entered into the logbook.

• The bMctrlTorqueMax status output of the

LS_DeviceMonitor

system block will be set to TRUE.

5.14.11

Motor speed monitoring

This function extension is available from version 12.00.00!

If the drive reaches the maximally permissible motor speed (

C00965

):

• The error response "Fault" occurs, i.e. the inverter is inhibited and the motor changes to torque-

free operation (coasts down).

• The error message "

oS2: Max. motor speed

" is entered into the logbook.

Note!

In the Lenze setting (

C00608

= "0: No Reaction"), the maximum torque monitoring is not