Parameter reference
16.2
Parameter list | C00456
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00456
C00458
C00459
C00461
C00462
Parameter | Name:
C00456 | Editor level
Data type: UNSIGNED_8
Index: 24119
d
= 5E37
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00458 | SYS_call table
Data type: UNSIGNED_16
Index: 24117
d
= 5E35
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00459 | SYS_Output table
Data type: UNSIGNED_16
Index: 24116
d
= 5E34
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00461 | Remote: Acceleration/deceleration time
Data type: UNSIGNED_32
Index: 24114
d
= 5E32
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
0.000
s
999.999
Subcodes
Lenze setting
Info
C00461/1
2.000 s
Remote: Acceleration/deceleration time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00462 | Remote: Control
Data type: UNSIGNED_16
Index: 24113
d
= 5E31
h
From version 06.00.00
Setting range
(min. value | unit | max. value)
0
65535
Subcodes
Lenze setting
Info
C00462/1
0
Remote: Control mode
C00462/2
0
Remote: Monitoring counter
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1