beautypg.com

16 parameter reference, 3 table of attributes – Lenze 8400 User Manual

Page 1099

background image

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05

1099

16

Parameter reference

16.3

Table of attributes

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02219

LS_WriteParamList: DC braking: Current

Linear value

22356

5754

A

4

INTEGER_16

100

C02220

LS_WriteParamList: Vp speed controller

Linear value

22355

5753

A

12

UNSIGNED_16

100

C02221

LS_WriteParamList: Ti speed controller

Linear value

22354

5752

A

12

UNSIGNED_16

10

C02222

LS_WriteParamList: SC: Tdn speed

controller

Linear value

22353

5751

A

4

UNSIGNED_16

100

C02223

LS_WriteParamList: Imax/M controller

gain

Linear value

22352

5750

A

8

UNSIGNED_16

100

C02224

LS_WriteParamList: Imax/M controller

reset time

Linear value

22351

574F

A

8

UNSIGNED_16

1

C02225

LS_WriteParamList: Vp current controller

Linear value

22350

574E

A

4

UNSIGNED_16

100

C02226

LS_WriteParamList: Ti current controller

Linear value

22349

574D

A

4

UNSIGNED_16

100

C02227

LS_WriteParamList: SC: Vp field controller Linear value

22348

574C

A

4

UNSIGNED_16

100

C02228

LS_WriteParamList: SC: Tn field controller Linear value

22347

574B

A

4

UNSIGNED_16

10

C02229

LS_WriteParamList: SC: settings

Selection list

22346

574A

A

16

UNSIGNED_8

1

C02230

LS_WriteParamList: Override point of field

weakening

Linear value

22345

5749

A

4

INTEGER_16

1

C02231

LS_WriteParamList: Rated motor power

Linear value

22344

5748

A

4

UNSIGNED_16

100

C02232

LS_WriteParamList: Motor rotor resistance Linear value

22343

5747

A

4

UNSIGNED_32

1

C02233

LS_WriteParamList: Motor stator

resistance

Linear value

22342

5746

A

4

UNSIGNED_32

1

C02234

LS_WriteParamList: Motor stator leakage

inductance

Linear value

22341

5745

A

4

UNSIGNED_16

100

C02236

LS_WriteParamList: Rated motor speed

Linear value

22339

5743

A

4

UNSIGNED_16

1

C02237

LS_WriteParamList: Rated motor current

Linear value

22338

5742

A

4

UNSIGNED_16

100

C02238

LS_WriteParamList: Rated motor

frequency

Linear value

22337

5741

A

4

UNSIGNED_16

1

C02239

LS_WriteParamList: Rated motor voltage

Linear value

22336

5740

A

4

UNSIGNED_16

1

C02240

LS_WriteParamList: Motor cosine phi

Linear value

22335

573F

A

4

UNSIGNED_8

100

C02241

LS_WriteParamList: Motor magnetizing

inductance

Linear value

22334

573E

A

4

UNSIGNED_16

10

C02242

LS_WriteParamList: Motor magnetising

current

Linear value

22333

573D

A

4

UNSIGNED_16

100

C02244

LS_WriteParamList: Auto-DCB: hold time

Linear value

22331

573B

A

4

UNSIGNED_32

1000

C02245

LS_WriteParamList: DC braking: Hold time Linear value

22330

573A

A

4

UNSIGNED_32

1000

C02246

LS_WriteParamList: Setting of motor

overload (I²xt)

Linear value

22329

5739

A

4

INTEGER_16

100

C02249

LS_WriteParamList: Oscillation damping

influence

Linear value

22326

5736

A

4

UNSIGNED_16

100

C02250

LS_WriteParamList: Filter time - oscill.

damping

Linear value

22325

5735

A

4

UNSIGNED_8

1

C02251

LS_WriteParamList: Oscillation damping

field weakening

Linear value

22324

5734

A

4

UNSIGNED_8

1

C02252

LS_WriteParamList: Kp position controller Linear value

22323

5733

A

4

UNSIGNED_16

100

C02256

LS_WriteParamList: Moment of inertia

Linear value

22319

572F

A

4

UNSIGNED_32

100

C02260

LS_WriteParamList: Speed sensor

selection

Selection list

22315

572B

A

4

UNSIGNED_8

1

C02261

LS_WriteParamList: SC: Field feedforward

control

Linear value

22314

572A

A

4

UNSIGNED_16

1

C02262

LS_WriteParamList: SC: Vp field

weakening controller

Linear value

22313

5729

A

4

UNSIGNED_16

10000

C02263

LS_WriteParamList: SC: Tn field

weakening controller

Linear value

22312

5728

A

4

UNSIGNED_16

10

C02264

LS_WriteParamList: Sensibility - Setpoint

feedforward control

Selection list

22311

5727

A

4

UNSIGNED_8

1

C02272

LS_WriteParamList: Motor phase direction

of rotation

Selection list

22303

571F

A

4

UNSIGNED_8

1 CINH

C02273

LS_WriteParamList: Speed limitation

Linear value

22302

571E

A

8

INTEGER_16

100

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

Grayed out = display parameter (read access only)