C00107 | dc braking: hold time, C00114 | diginx: inversion, C00107 – Lenze 8400 User Manual
Page 765: C00114, Fter the hold time, Inputs in, 16 parameter reference

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
765
16
Parameter reference
16.2
Parameter list | C00107
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00107
C00114
Parameter | Name:
C00107 | DC braking: Hold time
Data type: UNSIGNED_32
Index: 24468
d
= 5F94
h
Maximum hold time of the manual DC injection brake
• A time can be set here after which the DC injection brake is switched off automatically to prevent the motor from
thermal overload.
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.000 999.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00114 | DigInX: Inversion
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
The polarity of each digital input of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Info
Bit 0 Invert. DI1
Inversion of digital input 1
Bit 1 Invert. DI2
Inversion of digital input 2
Bit 2 Invert. DI3
Inversion of digital input 3
Bit 3 Invert. DI4
Inversion of digital input 4
Bit 4 Invert. DI5
Inversion of digital input 5
Bit 5 Invert. DI6
Inversion of digital input 6
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Invert CInh
Inversion of digital input RFR (controller enable)
Read access Write access CINH PLC STOP No transfer COM MOT