4device control (dctrl) – Lenze 8400 User Manual
Page 120

4
Device control (DCTRL)
4.3
Automatic restart after mains connection/trouble...
120
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Case 1: No controller enable at mains connection
If the controller is not enabled at mains connection, the controller remains in the "
status. Only with the controller enable, the device changes to the "
" status,
independent of the set auto-start option:
Case 2: Controller enable at mains connection and "Inhibit at power-on" activated
If the controller is enabled at mains connection and the auto-start option "Inhibit at power-on" is
activated, the controller remains in the "
" status. For changing to the
"
" status, the controller enable must first be deactivated. Only when the controller is
enabled again afterwards, the status changes to "
":
Case 3: Controller enable at mains connection and "Inhibit at power-on" deactivated
If in
the autostart option "Inhibit at power-on" is deactivated (bit 0 = 0), the status first
changes from "
connection with an enabled controller: