16 parameter reference – Lenze 8400 User Manual
Page 1054
16
Parameter reference
16.2
Parameter list | C02582
1054
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Bit 2 with hoist inv. feedfwd. control
Direction of feedforward control with vertical/hoist
technology:
• "0" ≡ Positive direction
• "1" ≡ Negative direction
Note:
Reversal (Ccw) is then considered.
Bit 3 Horizontal application
Direction of movement of the axis
• "0" ≡ The axis performs vertical movements.
Gravitational acceleration causes movements.
• "1" ≡ The direction of the axis is horizontal or rotary.
The gravitational acceleration does not cause any
movement.
Bit 4 Feedforward control C2581
From version 06.00.00
Selection of the feedforward control value
• "0" ≡ Automatic selection.
• The torque saved at the last stop is used.
• "1" ≡ Manual selection.
• bMBrakeStartValue2 = FALSE: The feedforward
control value 1 set in
• bMBrakeStartValue2 = TRUE: The feedforward
control value set in
is used.
Bit 5 Feedback monitoring
From version 06.00.00
Activation of status monitoring
• "1" ≡ The bMBrakeApplied input for status detection
of the brake (via a switching contact at the brake) is
monitored after the waiting time set in
has
expired.
Bit 6 SyncRampe L_NSet_1
From version 12.00.00
Selection of the ramp time for the synchronisation
process to setpoint speed after the brake opening time
has elapsed
Revised behaviour from version 12.00.00:
• "1" ≡ The ramp time of the effective acceleration of
the ramp function generator (
) is used
(Lenze setting).
• "0" ≡ As before, the ramp time set in
is used.
Note:
The changeover can be dynamically both via the ramp
parameter and via bit 6.
Bit 7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C02582 | Holding brake: Setting
Data type: UNSIGNED_8
Index: 21993
d
= 55E9
h