C02214 | ls_writeparamlist: switching frequency, C02215 | ls_writeparamlist: auto-dcb: threshold, C02214/1 – Lenze 8400 User Manual
Page 1023: C02214/2, C02214/3, C02214/4, C02215/1, C02215/2, C02215/3, C02215/4

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
1023
16
Parameter reference
16.2
Parameter list | C02214
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02214
C02215
Parameter | Name:
C02214 | LS_WriteParamList: Switching frequency
Data type: UNSIGNED_8
Index: 22361
d
= 5759
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Selection list
1 4 kHz var./drive-optimised
2 8 kHz var./drive-optimised
3 16 kHz var./drive-optimised
5 2 kHz constant/drive-optimised
6 4 kHz constant/drive-optimised
7 8 kHz constant/drive-optimised
8 16 kHz constant/drive-optimised
11 4 kHz var./min. Pv
12 8 kHz var./min. Pv
13 16 kHz var./min. Pv
15 2 kHz constant/min. Pv
16 4 kHz constant/min. Pv
17 8 kHz constant/min. Pv
18 16 kHz constant/min. Pv
21 8 kHz var./drive-opt./4 kHz min
22 16 kHz var./drive-opt./4 kHz min
23 16 kHz var./drive-opt./8 kHz min
31 8 kHz var./min. Pv/4 kHz min
32 16 kHz var./min. Pv/4 kHz min
33 16 kHz var./min. Pv/8 kHz min
Subcodes
Lenze setting
Info
C02214/1
2: 8 kHz var./drive-opt.
: c18_val1
C02214/2
2: 8 kHz var./drive-opt.
: c18_val2
C02214/3
2: 8 kHz var./drive-opt.
: c18_val3
C02214/4
2: 8 kHz var./drive-opt.
: c18_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C02215 | LS_WriteParamList: Auto-DCB: Threshold
Data type: UNSIGNED_16
Index: 22360
d
= 5758
h
From version 12.00.00 onwards
: Parameter values (1st value ... 4th value) for optional
Setting range
(min. value | unit | max. value)
0
rpm
60000
Subcodes
Lenze setting
Info
C02215/1
3 rpm
: c19_val1
C02215/2
3 rpm
: c19_val2
C02215/3
3 rpm
: c19_val3
C02215/4
3 rpm
: c19_val4
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1