2 parameter list, C00001 | keypad userlevel, C00002 | device command – Lenze 8400 User Manual
Page 738: C00001/1, C00002/31, C00002/32, C00002/33, C00002/29, C00002/30, Via the
16
Parameter reference
16.2
Parameter list
738
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
16.2
Parameter list
This chapter lists all parameters of the operating system in numerically ascending order.
C00001
C00002
Note!
The parameter descriptions are based on the software version V12.00.00.
Parameter | Name:
C00001 | Keypad Userlevel
Data type: UNSIGNED_8
Index: 24574
d
= 5FFE
h
From version 12.00.00 onwards
, the extent of menus, submenus and codes shown in the keypad can be adapted by
selecting the "userlevel".
• When the userlevel has been changed, the menus of the keypad will be reconfigured according to the selected
user level.
• Independently of the set userlevel, the parameters of the attached communication module will always be
displayed completely.
Selection list
Info
10 Standard
Only the most important menus and codes are displayed
on the keypad.
20 Expert
All menus and codes are displayed on the keypad.
30 Service
Only for servicing purposes (Lenze service).
Subcodes
Lenze setting
Info
C00001/1
10: Standard
Keypad UserLevel
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00002 | Device command
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h
Note:
• Before switching off the supply voltage after a device command has been executed, check the successful
execution of the device command via the status display in
• Before activating device commands by a master control, wait for the "Ready" signal of the controller.
• The device will reject a write process to C00002/x if the value is >1 and issue an error message.
:
Selection list
0 Off / ready
1 On / start
4 Action cancelled
5 No access
6 No access controller inhibit
20 20% working
40 40% working
60 60% working
80 80% working