C00354 | cobid, C00355 | active cobid, C00354/1 – Lenze 8400 User Manual
Page 812: C00354/2, C00354/3, C00354/4, C00354/5, C00354/6, C00354, C00355/1

16
Parameter reference
16.2
Parameter list | C00354
812
Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00354
C00355
Parameter | Name:
C00354 | COBID
Data type: UNSIGNED_32
Index: 24221
d
= 5E9D
h
Setting of the default COBID according to CANopen
• A change in the COBID will not be effective until a CAN reset node is performed.
Setting range
(min. hex value | max. hex value)
0x00000000
0xFFFFFFFF
Value is bit-coded:
Info
Bit 0 COBID Bit0
• Bit 0 ... 10: COB-ID
• Bit 11 ... 30: Reserved
• Bit 31: PDO invalid (is not transmitted)
... ...
Bit 31 PDO invalid
Subcodes
Lenze setting
Info
C00354/1
0x00000201
COBID CAN1_IN
C00354/2
0x00000181
COBID CAN1_OUT
C00354/3
0x00000301
COBID CAN2_IN
C00354/4
0x00000281
COBID CAN2_OUT
C00354/5
0x00000401
COBID CAN3_IN
C00354/6
0x00000381
COBID CAN3_OUT
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00355 | Active COBID
Data type: UNSIGNED_16
Index: 24220
d
= 5E9C
h
Display of the COBID of the PDOs that is active in the CAN stack
Display range
(min. value | unit | max. value)
0
2047
Subcodes
Info
C00355/1
Active COBID CAN1_IN
C00355/2
Active COBID CAN1_OUT
C00355/3
Active COBID CAN2_IN
C00355/4
Active COBID CAN2_OUT
C00355/5
Active COBID CAN3_IN
C00355/6
Active COBID CAN3_OUT
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1