Page 315

Lenze · 8400 protec HighLine · Reference manual · DMS 3.0 EN · 03/2013 · TD05
315
6
I/O terminals
6.1
Digital terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Counting behaviour
The following temporal characteristic shows the counting process depending on the signals of the
interfaces described before:
[6-1]
Transient characteristic of a quick counter block, sampling cycle = 1 ms
• The counter starts with the parameterised starting value.
• If the comparison value is reached or exceeded:
• The counter jumps back to its starting value.
• The output bCount1(5)_Compare is set to TRUE.
• If there is a FALSE-TRUE edge is at the input bCountIn1(5)_ResetCompare, the output
bCountIn1(5)_Compare can be reset to FALSE.
• If there is a FALSE-TRUE edge at the input bCountIn1(5)_LoadStartValue, the current counter
content can be reset to the parameterised starting value.
Related topics:
Using DI1(5) and DI2(6) as digital inputs
Using DI1(5) and DI2(6) as frequency inputs
Internal interfaces | System block "LS_DigitalInput"